44
The flue pipe and air inlet are the most important parts
that ensure the correct operation of the cooker.
In the event of particular circumstances of poor flue pipe
draught caused by particularly adverse weather conditions
(strong wind, low pressure, etc.) partially close the
internal
smoke damper
without closing it completely. Also adjust the
smoke damper on the flue pipe inlet.
Producing domestic hot water (suitable models only)
Domestic hot water is produced instantly via a double heat
exchanger immersed in water inside the heating
cooker/heating stove.
Therefore in order to have domestic hot water the heating
cooker/heating stove must reach a temperature of at least
65°C.
Set the heating cooker/heating stove to DHW output mode if a
large amount of domestic hot water is required:
“DHW mode”
(see
electronic control unit
).
The purpose of
“DHW mode”
is to
postpone the heating
pump start-up to higher temperatures so as to transfer all the
heat produced at these temperatures to domestic hot water.
In “
DHW mode”
it is possible to set a timer during which
pump start up is postponed to 85°C.
When DHW is no longer needed this function should be
deactivated (see
electronic control unit
).
If water is particularly hard, it is essential to install an anti
limescale device at the heat exchanger inlet, to be chosen
according to the water type.
Summary of Contents for K top
Page 1: ...INSTALLATION USE AND MAINTENANCE USEFUL ADVICE Heating cooker Heating stove User guide EN...
Page 2: ...2...
Page 5: ...5 HEATING COOKERS and HEATING STOVES models K top KP top and models TS top TSP top S R L...
Page 15: ...15 Top view of heating stove 600 665 622 275 515 170 150...
Page 49: ...49 Loosen the two hex screws on the inspection vent 1 2...
Page 50: ...50 Remove the vent as shown in the diagram and remove any deposits under the oven...
Page 63: ...63...