External air vent
Wood consumes oxygen when it burns. It is therefore
essential
that oxygen is reintroduced to the room in which
the heating cooker/heating stove is installed to prevent the air
in the room from becoming "heavy" and unbreathable.
It is mandatory
to install an external air vent with a minimum
passage of
at least 490 cm
2
(round hole with minimum
diameter of 25 cm; rectangular hole minimum size 20x25 cm).
STANDARD UNI 10683 FORBIDS THE DRAWING OF
COMBUSTION AIR FROM GARAGES, WAREHOUSES
WHERE COMBUSTIBLE MATERIAL IS STORED OR
FROM BUSINESSES WITH A FIRE HAZARD.
KEEP ALL OPENINGS FREE FROM OBSTRUCTIONS.