34
Control of any 3-way valve fitted for the DHW circuit
The heating cooker/heating stove is equipped as standard
with a control for a possible 3-way motorized valve to be
installed on the domestic hot water circuit.
(see wiring diagram
on page 30)
.
Inside the attachment compartment on the
heating cooker/heating stove, there is a cable with 4 wires that
can be used to control this valve. The four wires in the cable
have different colours, and precisely:
1.
Grey or blue wire
=
COMMON TO 3-WAY VALVE
2.
Black wire
=
HEATING COOKER/HEATING
STOVE SIDE
3.
Brown wire
=
GAS BOILER SIDE
4.
Yellow/green wire
=
GND
Below is an example of a connection using a 3-way valve with
spring return. Remember that the hydraulic connection must be
made in such a way that when the valve is at rest, the water
passes from the gas boiler. Only when the heating
cooker/heating stove temperature is sufficient (the value is set
from control panel) is the 3-way valve powered; it then closes the
gas boiler circuit and opens the heating cooker/heating stove
circuit.
MA
RRO
N
E
GI
ALLO
/V
ERD
E
G
RI
GI
O
O
BL
U
N
ERO
Valvola a 3 vie
N.B.: The brown wire can be used to control a service
relay if fitted.
Summary of Contents for K top
Page 1: ...INSTALLATION USE AND MAINTENANCE USEFUL ADVICE Heating cooker Heating stove User guide EN...
Page 2: ...2...
Page 5: ...5 HEATING COOKERS and HEATING STOVES models K top KP top and models TS top TSP top S R L...
Page 15: ...15 Top view of heating stove 600 665 622 275 515 170 150...
Page 49: ...49 Loosen the two hex screws on the inspection vent 1 2...
Page 50: ...50 Remove the vent as shown in the diagram and remove any deposits under the oven...
Page 63: ...63...