5.3.9.10 delays
delay Modules
Description
Attribute
Commands
Param
Value Range
Delay unit
Units
set, get
—
0 = milliseconds
1 = centimeters
2 = meters
3 = inches
4 = feet
Delay value
Delay_value
set, get, inc, dec
—
0 ~ max
Bypass
Bypass
set, get, toggle
—
0 = no
1 = yes
5.3.9.11 Controls
Level Control
Description
Attribute
Commands
Param
Value Range
Level mute
Muted
set, get, toggle
channel
(1 ~ channel_count (max: 16))
0 = unmuted
1 = muted
Level value
Level_dB
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
-100 ~ 12 dB
Maximum level value
Maximum
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
min ~ 12 dB
Minimum level value
Minimum
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
-100 ~ max
Level Control (Ganged)
Description
Attribute
Commands
Param
Value Range
Level mute
Muted
set, get, toggle
—
0 = unmuted
1 = muted
Level value
Level_dB
set, get, inc, dec
—
-100 ~ 12 dB
Maximum level value
Maximum
set, get, inc, dec
—
min ~ 12 dB
Minimum level value
Minimum
set, get, inc, dec
—
-100 ~ max
Level Inc/dec
Description
Attribute
Commands
Param
Value Range
Level mute
Muted
set, get, toggle
channel
(1 ~ channel_count (max: 16))
0 = unmuted
1 = muted
Level value
Level_dB
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
-100 ~ 12 dB
Maximum level value
Maximum
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
min ~ 12 dB
Minimum level value
Minimum
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
-100 ~ max
Inc and dec level value
Level_Inc_Dec
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
1 ~ 15
Ramp rate
Ramp_Rate
set, get, inc, dec
channel
(1 ~ channel_count (max: 16))
100 ~ 1000
Level ramp status
LevelRamp_Status
subscribe, unsubscribe
channel
(1 ~ channel_count (max: 16))
—
Level Inc/dec (Ganged)
Description
Attribute
Commands
Param
Value Range
Level mute
Muted
set, get, toggle
—
0 = unmuted
1 = muted
Level value
Level_dB
set, get, inc, dec
—
-100 ~ 12 dB
Maximum level value
Maximum
set, get, inc, dec
—
min ~ 12 dB
Minimum level value
Minimum
set, get, inc, dec
—
-100 ~ max
Inc and dec level value
Level_Inc_Dec
set, get, inc, dec
—
1 ~ 15
Ramp rate
Ramp_Rate
set, get, inc, dec
—
100 ~ 1000
Level ramp status
LevelRamp_Status
subscribe, unsubscribe
—
—