48
DM8000 User Manual
Examples
:
set Mixer1 Input_Mute 2 1;
Command format:
command InstanceTag Attribute channel_ID value;
dec Mixer1 Mix_Level 11;
Command format:
command InstanceTag Attribute value;
NOTE
:
This command does not require a
channel_ID.
toggle Mixer1 NOM_Gain_Enable 3;
Command format:
command InstanceTag Attribute channel_ID;
NOTE
:
This command does not require a
value.
Standard Mixer
Description
Attribute
Commands
Param
Value Range
Input mute
Input_Mute
set, get, toggle
channel
(value: 1 ~ input_count (max: 32))
0 = unmuted
1 = muted
Input level
Input_Level
set, get, inc, dec
channel
(value: 1 ~ input_count (max: 32))
-100 ~ 12 dB
Output mute
Output_mute
set, get, toggle
channel
(value: 1 ~ output_count (max: 24))
0 = unmuted
1 = muted
Output level
Output_Level
set, get, inc, dec
channel
(value: 1 ~ output_count (max: 24))
-100 ~ 12 dB
Level state
Level_State
set, get, toggle
input_ch, output_ch
(input_ch value: 1 ~
input_count (max 32); output_ch value: 1
~ output_count (max: 24))
0 = off
1 = on
Examples
:
set Mixer2 Input_Mute 2 1;
Command format:
command InstanceTag Attribute channel_ID value;
toggle Mixer2 Output_Mute 1;
Command format:
command InstanceTag Attribute channel_ID;
NOTE
:
This command does not require a
value.
set Mixer2 Level_State 2 1 3;
Command format:
command InstanceTag Attribute channel_ID1 channel_ID2 value;
NOTE
:
This command requires two
Channel_ID
designations
.
Matrix Mixer
Description
Attribute
Commands
Param
Value Range
Input mute
Input_Mute
set, get, toggle
input_ch
(value: 1 ~ input_count
(max: 32))
0 = unmuted
1 = muted
Input level
Input_Level
set, get, inc, dec
input_ch
(value: 1 ~ input_count
(max: 32))
-100 ~ 12 dB
Output mute
Output_mute
set, get, toggle
output_ch
(value: 1 ~ output_count
(max: 24))
0 = unmuted
1 = muted
Output level
Output_Level
set, get, inc, dec
output_ch
(value: 1 ~ output_count
(max: 24))
-100 ~ 12 dB
Level
Level
set, get, inc, dec
input_ch, output_ch
(input_ch value: 1 ~
input_count (max: 32); output_ch value:
1 ~ output_count (max: 24))
-100 ~ 0 dB
Level state
Level_State
set, get, toggle
input_ch, output_ch
(input_ch value: 1 ~
input_count (max: 32); output_ch value:
1 ~ output_count (max: 24))
0 = off
1 = on
NOTE
: Level_State
can support
set
commands for whole rows/columns and all cross points
:
Command InstanceTag Level_State A value;
Command InstanceTag Level_State R row_line value;
Command InstanceTag Level_State C column_line value;
Summary of Contents for DM8000