SONNENWIESE
PAGE 14
5000511/11.19
Maintenance
Maintenance of the high-intensity lamps
Continued
Removing the filter disks
1.
Hold the pane retainer (
7/1
).
2.
Hold the pane retainer with both hands and lift the filter disks
with both thumbs over the respective alignment stops (rivet or
angle) on the side opposite the quick-lock (
7/4
).
3.
Pull out the XTT filter disk (
7/3
) (mirrored) and the transparent
filter disk (
7/2
).
Cleaning the filter disks
1.
Clean the filter disks with warm water, adding a few drops
of washing-up liquid to the water if necessary.
2.
Dry the filter disks with a clean cloth.
3
4
1
2
2
5
6
1
7
8
7
Fitting the filter disks
Caution!
The device must not be used without the filter disks.
The coated side of the XTT filter disk faces the lamp.
It must be possible to read the KLAFS logo on the XTT
filter disk from the lounger.
Caution! When assembling:
The XTT filter disk (mirrored) is fitted on the user side, the
transparent filter disk is fitted on the lamp side.
Insert the two filter disks according to Fig. 6 and Fig. 7.
1.
Equip the pane retainer (
7/1
).
2.
Push the filter disks in over the respective alignment stop (rivet
or angle).
.
The filter disks latch in.
3.
Hang the fully mounted pane retainer (
8/6
) with the cleaned
filter disks into the recesses (
8/1
) of the GB-housing using the
pins (
8/5
).
4.
Swivel the pane retainer towards the GB-housing until the
pane retainer rests flush against it.
.
As a result, the pins of the micro switch (
8/7
) for the
BREAKSAFE safety device are pressed down.
5.
Press the quick-closure (
8/2
).
.
The pane retainer is firmly locked into the GB housing.
Closing the dust cover
'