Specifications only for technicians and Klafs
professionals - Installing the equipment
9.2.
Electrical connection - Configuration
The connection must only be established by a qualified
electrician in accordance with the valid DIN VDE
regulations, as well as accident prevention regulations.
14
1
2
3
9.2.1
Connecting the device
Switch off all fuses.
Arrange the fuse, RCCB switch
≤
30 mA and main switch on-site
according to applicable valid DIN/VDE/EVU regulations.
Fit a separation device in the fixed electrical installation, which is
provided with separation from the mains with a contact opening
of at least 3 mm on each pole.
The associated wiring diagram is supplied separately with each
device.
The device is supplied with a socket housing with a 4-m cable to
connect to the 1 N PE ~ 50 Hz, neutral conductor, grounding
conductor and signal cable. Insert the socket housing (
14/3
) into
the pin housing (
14/2
) mounted on the housing (
14/1
), and
secure the socket housing.
It is controlled by a 230-V switching signal which is supplied by a
switch, a push button, an external central control (coin-operated
timer) or an external timer.
When using a push button, the toggle switch must be set to ”T”.
The device is adjusted ex-works for a tanning duration of
20 minutes.
Caution!
The maximum tanning time must not be exceeded.
Continued on the next page