SONNENWIESE
PAGE 26
5000511/11.19
Specifications only for technicians and Klafs
professionals - Installing the equipment
Electrical connection - Configuration
Continued
9.2.3
Coin-operated timer
16
1
K4
K3
K2
Operating-hour meter
Toggle switch
17
Caution!
The connection must only be established by a qualified
electrician in accordance with DIN VDE 0100.
Disconnect the device from the mains.
Switch interface/coin-operated timer/timer: 230 V 50
Hz, phase position same as supply voltage.
See wiring diagram.
The run-time of the coin-operated timer or external timer switch
must match the time set via the K2/K4 time relay on the tanning
device (20 minutes ex-works). The K3 safety timing relay must then
accordingly be set to 22 minutes (110 % of the K2/K4 time).
If you prefer a
shorter tanning time
on the coin-operated timer than
20 minutes (device setting ex-works), please set the required time
on the timer switch (K2/K4) and on the safety timing relay (K3).
Adjust the K2/K4 timer switch to the same time as you set for the
coin-operated timer and then adjust the K3 safety timing relay to
110 % of the time that you set on the K2/K4 timer switch
(e.g. coin-operated timer and K2/K4 timer switch: 10 minutes, K3
safety timing relay: 11 minutes).
To have access to both timing relays, move the device to a
comfortable work position (see Section 5.3.) and remove the
cover plate (
16/1
).
Now the K2/K4 timer relay and the K3 safety timing relay are
accessible.
Caution!
The time set on the external coin-operated timer or the
external timer switch and the time set on the K2/K4
internal timer switch must not exceed 20 minutes.
The time set on the K3 internal safety timing relay must
not exceed 22 minutes.
Service chute
There are two service chutes (see Fig. 17) on the back of the
SONNENWIESE for carrying out maintenance and repair work.