SONNENWIESE
PAGE 31
5000511/11.19
Technical data, wiring diagram, installation
plans
Installation plans for concrete ceiling, timber-beam ceiling
Supply line 1/N/PE ~ 230 V
Fuse B 16 A
via FI I
ΔN
£
0.03 A
S
Coin
−
operated timer,
S
External timer switch
S
Push button
Line 4 x 1.5 mm
2
Suspended
ceiling
382
320
493
2003
1703
980
361.5
361.5
Wire cables
200
170
9
1
1
420
Ceiling cut
−
out 1720 x 420
Assembly information for concrete ceiling:
Weight approx.65 kg.
The ceiling must bear a load rating of 350 kg.
4 wire cables and
4 heavy
−
duty dowels
SONNENWIESE/lounger spacing, ideally 2000 mm
For revision purposes, keep a distance of 100 mm to the cover.
1
440
320
493
1703
980
361.5
361.5
Wire cables
1775
Housing encased with panel #3050502
Min. distance to ceiling 210 mm
1720
Supply line 1/N/PE ~ 230 V
Fuse B 16 A
via FI I
ΔN
£
0.03 A
S
Coin
−
operated timer,
S
External timer switch
S
Push button
Line 4 x 1.5 mm
2
Suspended
ceiling
382
320
493
2003
1703
980
361.5
361.5
Wire cables
300
170
9
420
Ceiling cut
−
out 1720 x 420
Assembly information for timber
−
beam ceiling:
Weight approx.65 kg.
The ceiling must bear a load rating of 350 kg.
4 wire cables, 4 clevises, 4 eye bolts
SONNENWIESE/lounger spacing, ideally 2000 mm
For revision purposes, keep a distance of 100 mm to the cover.
1
440
320
493
1703
980
361.5
361.5
Wire cables
1775
Housing encased with panel #3050501
Min. distance to ceiling 310 mm
1720
1
1
SONNENWIESE installation variation, concrete ceiling
SONNENWIESE installation variation, timber
−
beam ceiling