78
Installation
9.3 Ventilation and safety distances
• Make absolutely sure that the following conditions are met
for adequate ventilation of the hob
and that the supply and exhaust air is not blocked:
A
B
C
D
E
65
0mm
min.30mm
• The safety distance from the hob to the cooker hood must be
at least
650 mm
, and at least
760 mm
to wall units, shelves etc.
hanging above the hob.
• If the hob is installed above an oven, the oven must have its own
fan.
The safety distance between the bottom of the hob and the oven
must be at least
50 mm
.
• The installation must comply with all distance regulations and
other regulations.
A (mm)
B (mm)
C (mm)
D
E
Cooker hood:
resp. headroom hood:
Hanging furniture:
min. 650
min. 500
min. 760
min. 50
min. 20
Air gap /
intake
Exhaust air
min. 5 mm