Troubleshooting
Error code Meaning
What to do
Temperature sensor failure /
open circuit
Contact a certified electrician.
Temperature sensor failure /
short circuit
Temperature sensor failure
Sensor overheating
Wait until the hob has cooled down and
then switch it on again.
IGBT temperature sensor failure /
open circuit
Contact a certified electrician.
IGBT temperature sensor failure /
short circuit
IGBT overheating
Wait until the IGBT temperature has
dropped to a normal level and then
switch the hob back on.
If the cooling fan does not function nor-
mally, it must be replaced by a certified
electrician.
The supply voltage is below
the rated voltage.
Make sure that the power supply is
normal.
Then switch the hob back on.
The supply voltage is above
the rated voltage.
Communication error
Contact a certified electrician.
8.2 Error codes