Kiramek SCIBORG 825K Owner'S Manual Download Page 10

SCIBORG 825K OWNER’S GUIDE

5

Remote Start Failure.

 If the engine fails to start initially, the 825K will retry 

3 more times.  If the 825K fails to start the engine after 4 attempts, the start-

system will stop and the LCD pager will display the 

  icon.  The siren will 

also chirp 4 times and the pager will beep 4 times.

NOTE: The 825K will not start the engine under these 3 conditions: (1) the 

hood open, (2) the ignition key turned ON, (3) the brake pedal pushed (see H3-
16 on pg.21 of the Installation Guide).  If any of these conditions occur while 
the engine is remote started, the engine will immediately shutdown for safety.

Preset Engine Run Time.

 The engine is factory programmed to run for 10 min-

utes, but you can change the preset run time to 5, 15 or 20 minutes. 

See line 1 

on page 12 for details.

  When there is only 1 minute remaining before engine 

shutdown, the LCD pager will play a chime and then display 

.

Remote Engine Run Time.

  After  the  engine  has  been  successfully  remote 

started, you can easily increase the engine run duration from your pager or 

transmitter.  Simply press the    and 

  buttons at the same time to adjust 

the engine run time in increments of 5 minutes, for up to 20 minutes.  The 

LCD pager will display the changes you have made.  For example, if the LCD 

pager displays 

, it means you have chosen a “run time of 15 minutes.”

TIP:  Pressing and holding the    and 

  buttons for more than 2 seconds 

will display the “remaining engine run time” on the LCD pager.

NOTE: When the engine is not running, pressing the    and 

  buttons for 

any duration will display the current status of the vehicle on the pager.

Temperature Controlled Auto Start.

 The 825K can start your vehicle’s engine 

automatically  when  the  temperature  falls  below  a  specified  level. 

(See  page 

12, line 2.)

  To activate this feature, press and hold the 

  and 

  buttons 

for more than 2 seconds.  Press a second time to deactivate.  When activated, 

the siren will chirp 

once

 and the hazard/parking lights will flash 

once

.  The 

  icon will appear on the LCD pager along with the preset activation tem-

perature, and a melody will also play.  (If the preset temperature is -10°C, for 

example,  the  LCD  pager  will  display 

.)    Temperature  Controlled  Auto 

Start will allow a maximum of 6 start cycles in a 2 hour period.

Timed Auto Start.

  Press  and  hold 

  and 

  for  more  than  2  seconds  to 

have  the  825K  start  your  vehicle’s  engine  each  day  (every  24  hours)  at  the 

exact time you activate this feature.  The siren will chirp 

once

 and the pager 

will play a melody and display the 

  icon when active.  The pager will then 

beep 5 times, and the engine start sequence will begin.

Summary of Contents for SCIBORG 825K

Page 1: ...2005 KIRAMEK INC Aichi Japan Ver 1 0i Oct 05 2 WAY SECURITY REMOTE START...

Page 2: ...rt System The 825K is a state of the art device that will provide you with years of trouble free service if used properly Please familiarize yourself with the con tent of this User s Guide to get the...

Page 3: ...system that results from accidents improper use neglect faulty wiring incorrect installation modification removal or defacement of the product serial number al teration or repair outside Kiramek Inc o...

Page 4: ...rt 4 Remote Engine Shutdown 4 Keep Engine Running 4 Remote Start Failure 5 Preset Engine Run Time 5 Remote Engine Run Time 5 Temperature Controlled Auto Start 5 Timed Auto Start 5 Sensor Input Power 6...

Page 5: ...riggers 8 Other Trigger Zones 8 Panic Mode 9 Anti Carjack Mode 9 Page out Call 9 Secure Disarm 9 Valet Car Maintenance Mode 10 Program Switch Functions 10 Manual Disarming 10 Manual Arming 10 Transmit...

Page 6: ...tart Failed Set Engine Run Time Check Run Time Shutdown Engine Check Temperature Trunk Release CH 1 Siren Enable Disable Channel 2 Vehicle Locator Panic Mode Temp Auto Start ON Temp Auto Start OFF Dai...

Page 7: ...Light Impact 17 Daily Auto Engine Start Enabled 18 Incoming Page out Call 19 Temperature controlled Engine Start Enabled 20 RF Receive Active icon or Standby no icon 21 RF Transmit Active icon or Sta...

Page 8: ...n on your pager or transmitter The siren will then chirp twice ve hicle hazard parking lights will flash twice and the dome light will turn on Trigger Memory If the siren went off in your absence and...

Page 9: ...than 2 seconds The hazard parking lights will then flash 3 times and the LCD pager will play a melody alert and shortly after the icon will appear indicating the 825K is preparing to start the engine...

Page 10: ...D pager will display the changes you have made For example if the LCD pager displays it means you have chosen a run time of 15 minutes TIP Pressing and holding the and buttons for more than 2 seconds...

Page 11: ...ave the engine continue to run as normal simply by turning on the ignition with your key The engine will shutdown when you turn off the ignition Keyless Idling For turbo powered vehicles the 825K can...

Page 12: ...nce when the output is initiated The LCD pager will produce 1 beep after you release the button Channel 2 may be used in either armed or dis armed modes Programmable CHANNEL 2 Output If you do not int...

Page 13: ...Sensor Bypass Noise Pollution Attenuator The 825K will automatically bypass the sensor input once it has triggered the siren 8 times i e eight total Warning and or Full siren triggers Door trunk hood...

Page 14: ...Pressing the button any time during the 50 seconds will stop the siren Panic Mode This feature protects your vehicle in the event a thief stops you while driving To activate press and hold the and bu...

Page 15: ...sarm your 825K system if you have the ignition key Please note though that the siren will likely go off when you open the door to enter your vehicle However the siren will immediately stop when you ha...

Page 16: ...se with the system The feature set of the 825K can be easily customized via the Program Switch and the Programmable Features Menu shown on page 12 Programmable Features Menu NOTE Before changing menu...

Page 17: ...Warmer Delay Diesel 2 0s 10s 10s 2 0s 9 Door Lock Pulse Duration 0 8s 2 0s Double 30s Lck 10 2 Step D L or CH 3 CH 3 2 Step CH 3 2 Step Automatic Starter Kill ASK ASK off ASK off ASK on ASK on 11 Door...

Page 18: ...start output and press again to stop 6 Changes the tone of the siren chirp 7 Allows you to program the TACH input wire which is used to detect the engine running The default Noise TACH setting is sui...

Page 19: ...oor is open for more than 3sec after arming siren will chirp 4 times BLK WHT Output This wire can disable factory alarms for remote start This BLK WHT wire always sends a 200msec GND pulse when the re...

Page 20: ...t The red LED installed with your 825K system offers you with an at a glance view of system status via blinking patterns as shown in the table below Status LED Flash Codes System Status LED Flash Code...

Page 21: ...OFF 7th S 2 S stands for a short press while L stands for a long press 1 RF receiver sleeps power cut to 1 3 of normal 2 hour digit s selected for adjustment 3 minute digits selected for adjustment 4...

Page 22: ...NOTES...

Page 23: ...R E G I S T E R E D ISO 9001 BQR R E G I S TERED COM P A N Y P A T E NTS PEN D I N G W O R L D W I D E This product was built with care at a quality IS09001 registered manufacturing facility...

Page 24: ...SCIBORG is a registered trademark of KIRAMEK INC 9 183 1 Itayama cho Handa shi Aichi Ken 475 0936 JAPAN TEL 81 569 20 5585 FAX 81 569 20 5586 EMAIL support kiramek com...

Reviews: