Spectral range
(50% points)
Response time
(95%)
Response time
(63%)
Temperature response
Zero offsets
(a)
thermal radiation
(at 200 W/m²)
(b)
temperature change
(5 K/h)
Non-linearity
(100 to 1000W/m²)
Directional response
(up to 80° with 1000W/m² beam)
Field of view
Measurement range
Operating temperature range
Ingress Protection (IP) rating
310 to 2700 nm
< 0.2 s
Classification to ISO 9060:1990
Second Class
< 0.1 s
< 1 %
(-20°C to +50°C)
1 W/m
2
1 W/m
2
< 0.3%
< 20W/m²
180°
0 to 1500W/m²
-40°C to +80°C
67
Spectral range
(50% points)
Response time
(95%)
Response time
(63%)
Zero offsets
(b)
temperature change
(5 K/h)
Non-linearity
(100 to 1000W/m²)
Field of view
Measurement range
Operating temperature range
Ingress Protection (IP) rating
310 to 2700 nm
< 0.2 s
Classification to ISO 9060:1990
Second Class
< 0.1 s
1 W/m
2
< 0.3%
Temperature response
< 1 %
(-20°C to +50°C)
5° ±0.2°
Slope angle
1° ±0.2°
0 to 1500W/m²
-40°C to +80°C
67