MCVST42
Z46FK Fan Kit Installation
The fan can be installed through the
side of the fireplace.
If fireplace is already installed, the
burner pan must be removed to
install the fan (See Burner System
Removal section).
To install the fan from the side of the
unit, remove the two screws in the
Fan Access Cover on the left side of
the fireplace. Bend the cover up.
Insert fan through opening as shown.
Mount fan on tabs in bottom of fireplace. Connect fan as per wiring diagram below. Replace all components.
Fan Speed Control
may be located outside of fireplace.
Thermodisc
is
Located in track under firebox.
Remove Glass Doors from both sides of fireplace.
Remove UHS Box from bottom of fireplace.
Remove 2 screws from access door opposite flue side of
fireplace.
Slide Z46FK Fan Kit into opening.
Set fan onto Mount Tabs inside fireplace.
Thermodisc is located in track under firebox.
⚠
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three prong (grounding) plug for your protection against
shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from this.
Before Servicing
1. Ensure all power supply is shut off.
2. Label all wires prior to disconnecting when servicing control. Wiring errors can cause
improper and dangerous operation.
3. For fan servicing: Vacuum and clean lint/dirt build-up on the fan blades and motor.
4. When resealing the Burner Pan, use Mill Pac.
NOTE: Do not allow cords or wires to come into contact with the firebox or the underside of
the burner pan.
Fan Mount Tab
Fan
Thermo
Disc
Fan Speed
Control
(
May Be
Located
Outside of
Fireplace)
Power
42
Summary of Contents for MCVST42LP
Page 17: ...Fireplace Opening Required Clearance S1PF Surround 17...
Page 22: ...22...
Page 55: ...Gas Conversion for Modulator PART C 55...
Page 60: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 60...
Page 61: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 61...
Page 68: ...Proflame 2 Remote Control 68...
Page 70: ...70...