Cold Climates – CPI Setting - Proflame 2 Remote Control
Use the CPI setting during cold weather,
otherwise the fireplace may have a hard time starting up and establishing a
flame.
The
CPI
(Continuous Pilot Ignition) setting will keep the firebox and fireplace exhaust vent warm during cold weather.
When the firebox and exhaust vent are warm, exhaust gasses will
readily flow out of the firebox.
If the firebox and venting are too cold, there is resistance due to the
heavy cushion of cold air, and combustion gasses may not rise into the
exhaust vent, thus causing the fireplace to cycle or
Lockout
(if this
happens see
Lockout Reset Procedures
below).
NOTE:
The pilot system for this appliance may be equipped with a
Seven Day Timer
, in which case the pilot flame will be extinguished if
the main burner has not been turned ON for seven days. This Seven
Day Cycle is reset every time the main burner is cycled ON / OFF and
the pilot remains lit.If more than seven days has passed since the main
burner has been cycled ON / OFF and the pilot is also out, follow the
procedures described in this manual to light the pilot.
To switch from IPI to CPI Mode:
1.
Turn the fireplace OFF using the
ON / OFF Key
.
2.
Press the
Mode Key
. Display will appear as below.
3.
Press UP on the
UP / DOWN
Arrow Key
.
Display will show
CPI.
The module in the fireplace will
beep once to confirm command.
TO RETURN TO IPI
(INTERMITTENT PILOT) MODE:
Repeat steps one and two, and then press
DOWN on the
UP / DOWN Arrow Key
.
The module in the fireplace will beep once to
confirm command.
Lockout Reset Procedures – Proflame 2
If the fireplace has cycled too many times
in a short period of time, it will shut down
and become unresponsive to any new
command.
The LED light on the Proflame 2 module
in the fireplace will be flashing red.
This condition is a
Lockout
state.
Lockout Reset Procedure:
1. Disconnect power from the Proflame 2 module in the fireplace for 10
seconds. This includes removing the backup batteries.
2. Once the 10 second interval has passed, reconnect power and reinstall
backup batteries. The pilot should now try to light.
3. If the fireplace does not come on, call your fireplace technician.
LCD Display
ON / OFF Key
Thermostat Key
UP / DOWN Arrow Key
Mode Key
67
Summary of Contents for MCVST42LP
Page 17: ...Fireplace Opening Required Clearance S1PF Surround 17...
Page 22: ...22...
Page 55: ...Gas Conversion for Modulator PART C 55...
Page 60: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 60...
Page 61: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 61...
Page 68: ...Proflame 2 Remote Control 68...
Page 70: ...70...