Basic Finishing 2: MCVST42 With S1 or S1PF Surround
Step One: Remove Non-Combustible Header Strip. Frame
Fireplace with nailing tabs oriented as shown.
Step Two: Do not use Non-Combustible Header Strip on
top frame of fireplace. Use Concrete Board.
NOTE: Wall will be flush with fireplace face.
Step 3:
Once wall is completely finished, Screen with Surround
may be installed. Surround will conceal edges of fireplace.
IMPORTANT NOTE!
If installing tile, brick, or other
material around the perimeter of the surround:
You MUST Leave 4” of the face exposed around the fireplace
opening on the Sides, 4” at the Bottom for the S1PF, and S1
must be clear at Bottom. 4-1/16” must be exposed on the top.
This is to install and remove the Surround. See drawings below.
A Tile Lip Kit is available. Part Number ZCV-TLK.
Nailing Tab
Concrete Board
4-1/16” MIN
Fireplace
Opening
Drywall
4” MIN
Drywall
Concrete Board
Remove Non-Combustible
Header Strip
S1 or S1PF Surround
Required Clearance
S1 Surround
Drywall
Concrete Board
16