Specifications
1. Cold climate installation recommendation: When installing this fireplace against non insulated exterior wall or chase,
it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall must be
installed over insulation to prevent contact of insulation and unit.
2. Choose fireplace location and frame in accordance with the fireplace framing dimensions specified (see framing dia-
grams).
3. Drywall or other material can extend up to the various Stand-offs located on the side and top surfaces of the unit,
and flush with the bottom (see Stand-off Locations section). Please note that 1/2" facing material (e.g. drywall) can
be extended into the lower cavity of the unit.
4. When installing horizontal with a 90 degree bend maintain a minimum of two and a half inches [2.5"] above the
bend in enclosures.
5. A Hearth is not required for this unit.
For
Propane Horizontal Installations
the venting must be a minimum of one foot vertical off the flue before the elbow
on any horizontal runs of one foot or greater. This allows for cleaner combustion, and greatly reduces carbon deposits
and cleaning of glass. (Does not apply to Back Flue models)
Framing for your Gas Fireplace
Stand-off Locations
This section will cover four different types of installations: General, Corner, Raised, and Cabinet
installation. It is intended for qualified installers only.
Before beginning, make note of where the gas and electrical accesses are located on the unit. This
will streamline the construction process. Furthermore, familiarize yourself with the venting and clear-
ance requirements (see Venting section) for this appliance. Failure to comply with those requirements
can seriously compromise the safety and operation of the fireplace.
Please make note of where the stand-off
locations are. These stand-offs are provided
as indicators to illustrate the boundaries for
framing. Therefore, no construction material
is permitted to extend beyond these stand-
offs.
The Facing Material Lower Cavity is a chan-
nel designed to permit facing material (maxi-
mum of 1/2" thick) to extend into. The maxi-
mum extension allowed is 7/16” [1.1cm].
Mounting Tab Selection Guide
The Mounting Tabs are designed for
installation of two different configurations.
The first, as shown in Figure 3, is the Stud
Mount configuration, and the second is
the Cabinet Mount configuration.
8
Summary of Contents for Marquis Serenity MQZDV1917
Page 10: ...General Framing Installations Figure 5 General framing installation 10...
Page 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Page 34: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 34...
Page 35: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 35...