Mobile Home/Manufactured Housing Installation
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions
and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard
for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with
CAN/CSA Z240 MH Mobile Home Standard in Canada.
THE MQZDV1917N AND MQZDV1917LP MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES
AFTER FIRST SALE IN THE USA. IN CANADA THE MQZDV1917N AND MQZDV1917LP MAY BE INSTALLED
IN MANUFACTURED (MOBILE) HOMES.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian
National Electrical Code in Canada.
An appliance must be grounded to the steel chassis of the home with 8ga copper wire using a serrated or star
washer to penetrate paint or protective coating to insure grounding.
Use carriage bolt at the attachment point (see diagram above) to secure the appliance to the floor.
Warning: Do not compromise the structural integrity of the manufactured home wall, floor or
ceiling, during installation of appliance or venting.
For required venting components see venting installation in appropriate section of this manual.
Certified for installation in a bedroom or bed/sitting room. In Canada must be installed with listed
millivolt thermostat. In USA see local codes.
4
Summary of Contents for Marquis Serenity MQZDV1917
Page 10: ...General Framing Installations Figure 5 General framing installation 10...
Page 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Page 34: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 34...
Page 35: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 35...