Porcelain Liner Installation Guide

The installation procedure for the porcelain liner requires an additional mounting bracket: the
Porcelain Rear Bracket. This bracket is used to position both sides and the rear panel in place.
Note: It is imperative to position the panels tightly against the walls of the firebox to ensure proper
combustion and operation of the appliance.

CAUTION: Before operating the appliance, ensure that any screws removed from the fire-
box is returned to its original position for proper sealing. Check the condition of the screws
and their respective holes for signs of leakage. Refrain from operating the appliance and
consult a service technician immediately if leakage is found.

1.

Remove the glass door (see page 1

8

), and the Grate assembly by unfastening the two [2]

screws holding it in. Remove the two [2] back screws of both the Lower Latch assemblies.
NOTE: These screws will be used to fasten the Liner Holder brackets.

2.

Place the rear porcelain panel onto the back of the firebox.

3.

Slightly tilt the side panels and slide them into place. Raise the side panels and prop them on
the Liner Holder brackets. Ensure the side panels are tight against the walls of the firebox and
the rear panel. Adjust the Liner Holder brackets accordingly. Fasten the Liner Holder brackets
in place when the panels are tight against the walls of the firebox.

4.

Slide the Porcelain Rear bracket into the firebox and tightly against the rear panel. 

Be careful

not to scratch the porcelain finish of the panels.

Once all panels are tight against the fire-

box walls, fasten the Porcelain Rear bracket onto the baffle with the supplied self-piercing DT
screws.

5.

Reinstall any parts that were removed in the installation.

26

Summary of Contents for Marquis Serenity MQZDV1917

Page 1: ...al installations the venting must be a minimum of one foot vertical off the flue before going horizontal Installation Instructions Listed Certified for USA and Canada Model Number MQZDV1917 Stock s MQ...

Page 2: ...Fan Installation 20 22 Baffle Replacement Guide 22 Gas Line Installation 23 Burner Removal Servicing Guide 24 Brick Liner Installation Guide 25 Porcelain Liner Installation Guide 26 Millivolt System L...

Page 3: ...use odours It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time with the fan off after the curing of the paint has been completed These odours can last upw...

Page 4: ...ILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the steel chassis of...

Page 5: ...g the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequen...

Page 6: ...PA 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment s...

Page 7: ...ed Locating the Appliance The appliance can be located in the configura tions shown in Figure 2 Note that an Island installation with a top vent is possible as long as the horizontal portion of the ve...

Page 8: ...on and greatly reduces carbon deposits and cleaning of glass Does not apply to Back Flue models Framing for your Gas Fireplace Stand off Locations This section will cover four different types of insta...

Page 9: ...the unit Using the holes on the Front Tabs fasten the appliance to the Cabinet with the appropriate eight 8 screws Clearance to Combustibles Table 1 Clearance to combustibles for fireplace appliance B...

Page 10: ...General Framing Installations Figure 5 General framing installation 10...

Page 11: ...will be This formula is illustrated in Figure 5 Absolute Minimum Ceiling Height Min Ceiling Height Raised Height For cabinet installations It is necessary that the appliance be installed from the rea...

Page 12: ...Figure 7 Cabinet installation Note that the unit MUST be installed from the back of the cabinet Figure 8 Dimensions for facing material cutout 12...

Page 13: ...fireplace vent opening When using paint or lacquer to finish the mantel such paint or lacquer must be heat resistant 250 F 121 C to prevent discoloration Example If a mantel is desired to extend 4 1...

Page 14: ...ith a sidewall i e a wall perpendicular to the face of the unit must adhere to the clearances imposed by the illustration shown in Figure 10 Figure 10 Sidewall clearance requirements Sidewall Clearanc...

Page 15: ...n in the Dimensional Overview section NOTE Only one 2x4 stud header may be used in the frame Please refer to Figure 5 on page 10 or Figure 11 below To ensure the Front Surround covers the maximum area...

Page 16: ...en the finished NOTE This Surround is capable of extending 5 8 away from the front of the unit Hence a wider range of facing materials can be accommodated without relocating the unit 4 To remove the F...

Page 17: ...hown in Figure 14 3 Using the thumb screws washers and locking nuts provided fasten the Access Panel Grill to the Finishing Surround frame Observe the locations of the screw washer and nut Torque the...

Page 18: ...efore recommended that initially the glass be cleaned two or three times with non abrasive common household glass cleansers and warm water After that the glass should be cleaned two or three times a s...

Page 19: ...ion of the frame is IN FRONT of the Upper Mounting Tab and the lower portion is BEHIND the Lower Mounting Tab Figure 17 Arch Door installation 3 Swing the right side of the Arch Door into the unit Pos...

Page 20: ...he fan directly simply connect the TERMINAL B wires to the thermal switch Thermodisc terminals 2 To have a unit mount variable control controlling the fan speed in conjunction with thermal switching s...

Page 21: ...an kit power cord from the receptacle and the two 2 leads from the variable speed control thermal switch Remove the Burner Pan assembly Refer to the Burner Removal Servicing Guide section 2 Lift the f...

Page 22: ...Please make note of their location before beginning the replacement procedure IMPORTANT Examine the condition of the mounting holes and screws It is required that these areas are sealed properly If t...

Page 23: ...olution 8 The appliance and its individual shutoff valve must be disconnected from the gas supply pip ing system during any pressure testing of that system at test pressures in excess of 1 2psig 3 5 K...

Page 24: ...llation is the reverse of these steps NOTE Before reinstallation ensure that all old sealant material is scraped off and removed from the fire box bottom and burner pan Verify that the sealing area is...

Page 25: ...rner tube by sliding it towards the right hand side 4 If the Upper Clips 2 and Lower Panel Brackets 2 are preinstalled then remove them 5 Tilt the Back Panel backwards and slide it into place The Back...

Page 26: ...bly by unfastening the two 2 screws holding it in Remove the two 2 back screws of both the Lower Latch assemblies NOTE These screws will be used to fasten the Liner Holder brackets 2 Place the rear po...

Page 27: ...above on this label If you don t smell gas then go to the next step 7 Now push in the control knob slightly and turn 4 counter clockwise to the PILOT position 8 Push in the control knob all the way a...

Page 28: ...d also be inspected monthly to ensure proper operation Flame should appear similar to the above picture Conversion Kit Instructions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 100...

Page 29: ...ght and remove it from the assembly Make note of where the Air Shutter is and the screw used to secure it 3 Remove the main orifice using a 1 2 wrench and replace it with the new conversion kit orific...

Page 30: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Page 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...

Page 32: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Page 33: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Page 34: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 34...

Page 35: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 35...

Page 36: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Page 37: ...combustion air inlet to any other appliance In Canada 6in 15cm for appliances 10 000 BTUh 3kW 12in 1 30cm minimum for 1 In accordance with the current CSA B149 1 Natural Gas and Propane Code 2 In acc...

Page 38: ...Top of horizontal is 1 1 2 3 8cm Top of 90 degree elbow in an enclosure over 44 112cm is 2 1 2 6 4cm Venting terminal shall not be recessed into a wall or siding Venting Routes and Components Since it...

Page 39: ...2 20 6 1 8 2 4 20 6 1 18 5 5 20 6 1 9 2 7 20 6 1 19 5 8 20 6 1 10 3 0 20 6 1 20 6 1 20 6 1 11 3 4 20 6 1 25 7 5 15 4 6 12 3 7 20 6 1 30 9 0 10 3 0 13 4 0 20 6 1 40 12 2 0 0 Table 2 Horizontal Vent Ta...

Page 40: ...alling the pipe expand it com pletely and then cut off the remaining length A flex pipe can be expanded to twice their shipped length e g 4ft to 8ft Do not use more than 2 couplers to extend short pip...

Page 41: ...ealant NOTE It is critical to the proper and safe operation of this fireplace that on all connections the inner liner and the outer casing are both caulked with liberal amounts of sealant Do not use a...

Page 42: ...ent Termination must not be recessed into wall or siding Figure 26 Side wall hole dimensions for flush wall installations For other installations where the unit is far away from the wall ensure that t...

Page 43: ...uring the flex and rigid pipe are secured 4 flex pipe must be secured the same way with 4 screws but must penetrate the 4 flex and 4 section of termination Attach 7 rigid pipe to 7 termination with se...

Page 44: ...the plate to the roof deck then cement the shingles to the plate with a suitable waterproof mastic Ensure that the chimney is plumb Square up the flashing plate and nail in place to the roof deck Use...

Page 45: ...re to do so will result in improper combustion and emission of harmful gases and can lead to personal injuries Figure 29 Log C 19 parts list Figure 29 Log C 19 parts list Figure 31 Step 1 Place LOG 1...

Page 46: ...e 35 Step 5 Place Ember Rocks on the front burner tube and ember plate as shown DO NOT PLACE EMBER ROCKS ON THE REAR BURNER TUBE Figure 36 Step 6 Place Lava Rock on the bottom of the firebox IN FRONT...

Page 47: ...9FK Fan Kit w Variable Speed Temperature Sensing MQ19PL Porcelain Reflective Panel Liner MQ19RL Brick Liner Z1MT Thermostat Millivolt Wall Mount Z80PT Thermostat Programmable Digital Millivolt Millivo...

Page 48: ...zontal Square Termination Vent Starter Kit 3 Length Horizontal Vent Termination Wall Thimble Wall Thimble 36 Flex Pipe Mill Pac FDVVT40 Vertical Vent Termination FDVHT Horizontal Round Termination FDV...

Page 49: ...ge Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Rep...

Page 50: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Reviews: