Before joining pipes, apply a bead of high temperature sealant (Mill Pac) to end of pipe. First
attach the 4" flue pipe to the vent termination with sealant, and secure with the four screws provid-
ed. At this time make sure the spacer springs are attached to the 4" flex pipe as required. Then
attach the 7" pipe by the same method.
Mount vent termination and seal to wall using caulking around the wall thimble to weather proof.
After installing the vent termination, double check to make sure the pipe extends properly through
wall thimble and into vent termination.
Before joining pipes to fireplace flue, apply a bead of high temperature sealant (Mill Pac) to end of
pipe. First attach the 4” flue pipe to fireplace with sealant, and secure with the four screws provid-
ed. At this time verify that the spacer springs are attached properly to the 4" flex pipe as required.
Then attach the 7" pipe by the same method.
Support horizontal pipes every 2ft [61cm] with metal strap bands. Recheck fireplace to make sure
it is leveled and properly positioned and secured. Support vertical pipes to maintain a minimum of
1" or greater clearance to combustibles with metal strapping bands.
Note: Vent Termination must not be recessed into wall or siding.
Figure 26 - Side wall hole dimensions for
flush wall installations
. For other installations where the unit is far
away from the wall, ensure that the vertical rise is 1/4" for every 12” of horizontal run.
Venting Straight Up Through Roof
An Attic Insulation Shield must be installed where the vent passes from a lower living space into
an attic space where the chimney is not enclosed. It is designed to keep insulation materials away
from the chimney (see Figure 28a).
When installing the Attic Insulation Shield where the chimney passes from a living space to an
attic space, install the shield from below and nail in place using 1" spiral nails.
A fire stop must be installed on the bottom side of the joists when passing through a ceiling or
floor. If an attic insulation shield is to be used, a fire stop is not required.
Using Flex Bends
Avoid cutting joists by offsetting the flex pipe (see Figure 28b).
When using 45° bends a bend support is required directly above the highest bend.
When installing a bend in a joist area a minimum of 2-1/2" [6.4cm] clearance to combustible to the
top of bend must be maintained, sides and bottom of pipe, a 1" [2.5cm] clearance to combustibles
must be maintained. If running horizontal through an area a 1-1/2" [3.8cm] minimum clearance to
the top of the horizontal pipe must be maintained.
42
Summary of Contents for Marquis Serenity MQZDV1917
Page 10: ...General Framing Installations Figure 5 General framing installation 10...
Page 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Page 34: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 34...
Page 35: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 35...