6
Air flow test
1. Disconnect the air hose from the blower.
2. Attach the air flow indicator to the unit.
3. Turn on the blower. If the blower unit does not provide at least 160
lpm of air, ensure the use of clean pre-filters and filters and a fully
charged battery and re-try. If the problem persists, follow the
troubleshooting instructions or contact the manufacturer.
Troubleshooting
Belt
The waist belt holds the blower unit to the lower back. The buckles snap
together. The buckles are released by squeezing the top and bottom of
buckle.
DO NOT POSITION THE BLOWER UNIT ON THE FRONT OF THE BODY
OR WHERE IT CAN BE EXPOSED TO SPARKS.
Belt Adjustment
1. Adjust the length of the belt by sliding the belt through the
buckles to reach the desired length.
2. Adjust the elastic keepers to secure the loose tails of
the belt.
Belt Removal and Replacement
1. To remove the belt from the blower, depress the plastic
tabs on the inside of the belt near the blower unit to release
the belt attachment clips from the blower unit.
2. To attach the belt to the blower, snap the attachment clips
onto the rails on the blower. Note that there is a left and right side to
the belt and clips will only attach when correctly aligned.
Malfunction
Possible cause
Recommendations
The unit is not working at all
The battery is discharged
(verification: the unit is working with a different fully
functional battery).
A defect in the motor, electronics or the charging
connector.
Charge the battery
(if the problem persists, replace the battery).
Contact customer service.
Low air flow
The air hose or air distribution system is blocked.
The air is leaking through gaps.
The battery is out of power.
The filters are clogged.
Check and eliminate any possible obstacle.
Check all sealing elements and connections; check whether
the hose is damaged and without leaking spots.
Charge the battery.
Change the filters.
The unit is working only for a short time.
The filter is clogged.
The battery is not charged sufficiently.
Change the filter.
Charge the battery. (If the problem persists,
replace the battery.)
It is not possible to charge the battery.
Charger malfunction.
Faulty battery connector.
Contact customer service.
Check the battery’s contact
It is not possible to charge the battery suf-
ficiently enough.
The battery’s life cycle is at its end.
Replace the battery.
If there is any defect, fault, a sudden decrease or increase of air supply whilte the user is working in a contaminated working place, it is absolutely
necessary to leave the site immediately and verify the following:
• PAPR is properly assembled.
• Battery has power
• No obstructions or blockages, such as kinked hose or blocked filters
• Filters are not clogged
• No damage to the unit, such as perforated or cracked hose, blower or filter.
• Face seal is not damaged.