LIST OF WARNINGS WITHIN THESE USER INSTRUCTIONS.
THESE USER INSTRUCTIONS, INCLUDING ALL WARNINGS, CAUTIONS, LIMITATIONS AND INSTRUCTIONS MUST BE READ IN FULL AND FOLLOWED CAREFULLY
BY ALL USERS, ISSUERS AND THOSE RESPONSIBLE FOR MAINTENANCE. FAILURE TO CAREFULLY FOLLOW ALL WARNINGS, CAUTIONS, LIMITATIONS AND
INSTRUCTIONS COULD REDUCE THE PROTECTION OF THE PAPR AND CAUSE SERIOUS INURY, ILLNESS OR DEATH.
WARNING
DO NOT CHARGE THE BATTERY IN AREAS OF
EXPLOSIVE OR COMBUSTIBLE GASES OR VAPORS.
EXPLOSION OR FIRE MAY RESULT. USE ONLY THE
JACKSON SAFETY* R60 AIRMAX ELITE* BATTERY
CHARGER TO CHARGE THE JACKSON SAFETY*
R60 AIRMAX ELITE* BATTERIES. DO NOT USE THE
BATTERY OR CHARGER IF THE CORD IS WORN
OR FRAYED, OR IF THE HOUSING IS CRACKED,
DEFORMED OR MELTED. USING A DAMAGED
BATTERY OR CHARGER MAY RESULT IN SERIOUS
INJURY OR DEATH.
FAILURE TO PASS A USER PERFORMANCE CHECK
AND COMPLETE ALL NECESSARY REPAIRS BEFORE
USE MAY ADVERSELY AFFECT RESPIRATOR
PERFORMANCE AND RESULT IN ILLNESS OR DEATH.
DO NOT USE THE JACKSON SAFETY* R60 AIRMAX
ELITE* PAPR BLOWER WITHOUT (1) FULLY
INSPECTING ALL COMPONENTS FOR WEAR,
LOOSENESS OR OTHER DAMAGE; (2) PERFORMING A
FLOWRATE PERFORMANCE CHECK IN ACCORDANCE
WITH THESE USER INSTRUCTIONS; (3) PERFORMING
ALL NECESSARY REPAIRS. FAILURE TO PROPERLY
INSPECT AND CHECK PERFORMANCE ADN REPAIR
MAY RESULT IN SERIOUS INJURY, ILLNESS OR
DEATH.
DO NOT ALLOW WATER OR LIQUIDS TO ENTER ANY
PART OF THE BLOWER UNIT, FILTERS, OR BATTERY
COMPARTMENT. DO NOT CLEAN WITH SOLVENTS. DO
NOT ATTEMPT TO CLEAN FILTERS BY KNOCKING OR
BLOWING OUT FOREIGN MATERIALS. THESE
ACTIONS MAY DEGRADE OR DAMAGE COMPONENTS
AND MAY RESULT IN HAZARDOUS EXPOSURES THAT
MAY RESULT IN SERIOUS INJURY, ILLNESS, OR
DEATH.
DO NOT ALTER OR MODIFY ANY PART OF THE PAPR
IN ANY WAY. DO NOT ATTEMPT TO REPAIR THIS PAPR.
NEVER ATTEMPT TO MODIFY A FILTER TO FIT A
BLOWER UNIT FOR WHICH IT IS NOT CE APPROVED.
IMPROPER ALTERATIONS, MODIFICATIONS,
OR REPAIRS MAY DEGRADE THE PROTECTIVE
PERFORMANCE OF THE PAPR AND RESULT IN
SERIOUS INJURY, ILLNESS OR DEATH.
DO NOT USE WITH PARTS OR ACCESSORIES
NOT MANUFACTURED BY KIMBERLY-CLARK
PROFESSIONAL* AND SPECIFICALLY IDENTIFIED
AS COMPATIBLE WITH THIS JACKSON SAFETY*
R60 AIRMAX ELITE* PAPR. USE ONLY AUTHORIZED
JACKSON SAFETY* R60 AIRMAX ELITE* PARTS AND
ACCESSORIES WHICH ARE INCLUDED IN THE CE
APPROVAL LABEL. FAILURE TO USE APPROVED PARTS
AND ACCESSORIES WILL VOID NIOSH APPROVAL AND
KIMBERLY-CLARK PROFESSIONAL*’S WARRANTY
AND COULD RESULT IN SERIOUS AND PERMANENT
INJURY, ILLNESS OR DEATH.
LEAVE THE CONTAMINATED AREA IMMEDIATELY IF:
• THE MANUFACTURER’S MINIMUM DESIGN FLOW
WARNING ALARMS
• BREATHING BECOMES DIFFICULT
• YOU FEEL DIZZY, DISTRESSED, OR HAVE IMPAIRED
VISION
• ANY PART OF THE PAPR BECOMES DAMAGED
• YOU SMELL OR TASTE THE CONTAMINANT OR
YOUR EYES, NOSE OR MOUTH BECOME IRRITATED
• AIRFLOW INTO THE RESPIRATOR DECREASES
OR STOPS
FAILURE TO IMMEDIATELY LEAVE THE CONTAMINATED
AREA IF THE PAPR IS NOT OPERATING PROPERLY
CAN RESULT IN SERIOUS INJURY, ILLNESS OR DEATH.
IMPORTANT
These User Instructions must be followed carefully by all
users, issuers and those responsible for maintenance.
This PAPR must be used, issued or maintained only by
properly trained and qualified personnel and in accordance
with these User Instructions. Failure to carefully follow
all warnings, cautions, limitations and instructions could
reduce the protection of the PAPR and result in
serious injury, illness or death. Do not use for overhead
welding where there is a falling molten metal hazard. This
welding helmet/filter system does not provide protection
from molten metal and spatter during overhead welding.
Intended Use
This product helps protect against certain airborne
contaminants. For proper use, see
your supervisor, user instructions, or the standard
EN12941 The JACKSON SAFETY* R60 AIRMAX
ELITE R60 respiratory system must NOT be used in an
environment where life or health are directly endangered
(IDLH). Oxygen concentration in the surrounding area
must not drop under 17%. Type and concentration of the
contaminants in the working place must be known to the
user. This PAPR system must not be used in unventilated
areas such as tanks, pipes, canals etc.
The PAPR system must not be used in areas with danger
of explosion.
The JACKSON SAFETY* R60 AIRMAX ELITE* respiratory
system is supplied together with particle P R SL filter and
thus it protects the user in environments contaminated
with particles.
WARNING
Violation of any of the conditions of use voids the warranty.
Replace the filters every time you feel a change of smell in
the air coming in from the unit.
Use ONLY certified original filters designed for your
respiratory unit!
Use the respiratory system only with the blower unit
switched on. (If the blower unit is switched off, the
respiratory system incorporating a hood gives little or no
respiratory protection. Also there is a risk of high
concentration of carbon dioxide (CO2) and of oxygen
reduction inside the headpiece.)
Check the air flow before use.
If the blower unit stops working for any reason, the user
must leave the contaminated area immediately.
Attention! During a period of really hard work, pressure may
decrease inside the hood if the user’s breathing becomes
too intense and thus the protective effect can decrease.
Make sure that the headpiece fits the user’s face perfectly.
Only then the efficacy of the system is sufficient. The
protective effect of the complete system is reduced if the
seal of the headpiece is not fitted properly, for example,
due to beards or long hair breaking the seal. Make sure that
the air hose doesn‘t make a loop and doesn’t get caught on