Command (Function)
Measured Value Queries
The second level nodes are SEQuence3 and ACQuire. Regardless of which node you use, the
PCR operates in the same way when it receives the commands.
If you use the root node MEASure, the measurement is performed, and then the measured
value is queried. If you use FETC, the measured value is queried without a measurement
being performed.
Sets the trigger source of the sequence 3 group
Starts the trigger function of the sequence 3 group
Starts the trigger function of the specified sequence group
Sequence 3 group software trigger
Sets the auto continue mode
Sets the averaging period of measured values
Aborts the trigger function
Queries the DC current
Queries the AC current
Queries the peak current
Sets the hold time of the peak current
Queries the peak current (the held value)
Clears the held measured peak current
Queries the frequency
Queries the AC power (the actual power)
Queries the AC power (the apparent power)
Queries the AC power (the reactive power)
Queries the power factor of the AC power
Queries the DC power
Queries the DC voltage
Queries the AC voltage
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
16/166