![Kikusui PCR-M Series Communication Interface Manual Download Page 115](http://html.mh-extra.com/html/kikusui/pcr-m-series/pcr-m-series_communication-interface-manual_1966803115.webp)
*OPT/ SYST:OPT
Queries the optional interface board that is installed in the PCR.
並列運転時には、マスタ機に装着されているオプションインターフェースボードを問い合わせます。
単相
3
線出力時または三相出力時には、
U
相に装着されているオプションインターフェースボードを問い
合わせます。
Command
*OPT?
SYST:OPT?
Response
Returns the optional interface board that is installed in the PCR in comma-separated string
format in response to OPT?/SYST:OPT?. Returns 0 in response to *OPT?/SYST:OPT? if there
is no option installed.
"MP-3P05" 3P05-PCR-LE Three-phase output driver
"MP-2P05" 2P05-PCR-LE Single-phase, three-wire output driver
"PD05"
PD05-PCR-LE Parallel operation driver
"EX05"
EX05-PCR-LE Analog signal interface
"EX06"
EX06-PCR-LE Analog signal interface
"USB"
US05-PCR-LE USB interface board
"GPIB"
IB05-PCR-LE GPIB interface board
"LAN"
LN05-PCR-LE LAN interface board
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
115/166