INIT:CONT:NAM (PCR-M series only)
Sets the sequence operation auto continue mode of the specified sequence group.
When the sequence operation auto continue mode is turned on
If the trigger source parameter is set to IMM, the change or measurement starts
immediately. When the operation is complete, a new change or measurement
automatically starts.
If the parameter is set to BUS, the change or measurement starts after receiving a
software trigger. When the operation is complete, the PCR-M/ PCR-LE waits for the next
trigger.
When the sequence operation auto continue mode is turned off
The change or measurement currently in progress continues unless ABOR is sent. The
operation does not automatically continue to the new change or measurement.
Command
INITiate:CONTinuous:NAME {TRANsient|ACQuire},{ON|OFF|1|0}
INITiate:CONTinuous:NAME?
Parameter {TRANsient|ACQuire}
Value TRAN SEQuence1
ACQ
SEQuence3
Parameter {ON|OFF|1|0}
Value ON(1) Auto continue mode on
OFF(0) Auto continue mode off (default)
For the setting that is applied when *RST is sent, see this
Response
Response
Returns the sequence operation auto continue mode setting using a string and NR1 foratm
in response to INIT:CONT:NAME? {TRAN|ACQ}.
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
104/166