If a value that cannot be assigned is entered, the device rounds the value to the closest
possible value.
SOURce:FREQuency 1100
PCR-M: The range of values for frequency is 40 to 500. Thus, 500 is set even if 1100 is
specified.
PCR-LE/PCR-LE2: The range of values for frequency is 1 to 999.9. Thus, 999.9 is set even if
1100 is specified.
Special form numeric parameters
The special form numeric parameters MINimum, MAXimum and DEFault can be used as
substitutes for limit values when the parameter is numeric.
In the example below, the current limit is set to the minimum value.
SOURce:CURRent MINimum
Queries can be used to inquire the minimum and maximum values for most parameters.
SOURce:CURRent? MAX
SOURce:CURRent? MIN
Measurement units
Below are the default measurement units. Commands are accepted even if measurement
units are not specified.
·V
(
voltage
)
·A
(
current
)
·W (wattage)
·VA (apparent power)
·VAR (reactive power) ·DEG (degrees) ·HZ (frequency)
The following optional prefixes are supported. If you use optional prefixes, specify the
measurement unit.
·M
(
milli
)
·K
(
kilo
)
·U
(
micro
)
NOTE
· The unit symbols in the International System of Units (SI) contain lowercase characters. The
IEEE standard uses uppercase characters. SCPI commands are not case-sensitive.
· Commands are accepted even if a measurement unit is not specified.
· To enter "µ" in the data, use "U" instead.