MEAS:CURR:AC/ FETC:CURR:AC
MEAS:CURR:AC? starts a new measurement and then queries the AC current.
FETC:CURR:AC? queries the AC current without starting a new measurement.
The valid modes (parameters to the
command) are AC, ACDC, EAC (PCR-M
only), and EDC (PCR-M only).
Command
MEASure[0][:SCALar]:CURRent:AC?
FETCh[0][:SCALar]:CURRent:AC?
Response
Returns the AC current in NR3 format in response to MEAS:CURR:AC? or FETC:CURR:AC?.
In case of the single-phase three-wire output, MEAS:CURR:AC? or FETC:CURR:AC? returns a
comma-separated list of the AC current <NR3> for U and V phases.
In case of the three-phase output, MEAS:CURR:AC? or FETC:CURR:AC? returns a comma-
separated list of the AC current <NR3> for U, V, and W phases.
Unit
:
A
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
132/166