Tutorial
Error Checking
Error/event queue
The SCPI specifications define a standard error reporting scheme, Error/Event Queue. This is
a FIFO (First In First Out) queue, which records errors and events. The maximum number of
errors/events that the PCR can record is 255. Each error/event can be read with the
SYSTem:ERRor query.
The response to this query contains a numeric part (error/event number) and a textual
description, such as:
The error/event queue is empty when the *CLS common command is sent, when the last
item in the queue is read, and when the PCR is turned on. When the error/event queue is
empty, the query returns the following:
0,"No error"
Displaying communication errors
The PCR has a debug trace function.
The oldest item among the errors and events (if they are present) can be displayed on the
PCR. This function is convenient when you debug your remote applications.
While an error/event item is displayed on the panel, the normal voltmeter and ammeter are
disabled.
If the error/event queue is empty, the debug trace function does not display any errors.
Sending the *CLS command clears the communication error display.
If in local mode, the debug trace function is temporarily disabled.
The communication error display can be enabled or disabled with the SYSTem:ERRor:TRACe
command.
SYSTem:CONFigure:TRACe {ON|OFF}
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
68/166