Operation and Features
2
Keysight U8030A Series User’s Guide
53
4 Enable the OVP.
– Press the
[Over Voltage]
button again to end the adjustment and enable
the OVP.
– The display will show
dOnE
.
– The corresponding OVP annunciator (
OVP1
or
OVP2
) turns on.
Disable the OVP
1 Select an output channel with OVP enabled.
– Press
[1]
to select Output 1, or
– Press
[2]
to select Output 2.
– The corresponding annunciator (
OUT1
or
OUT2
) turns on.
2 Disable the OVP.
– Press the
[Over Voltage]
button again to disable the OVP.
– The corresponding OVP annunciator (
OVP1
or
OVP2
) turns off.
Clear the overvoltage condition
The OVP trip can only occur if the corresponding output is enabled. When the
OVP trip occurs, the corresponding output is disabled automatically.
– If the OVP trip occurs on Output 1, the display shows
triP
on line 1 and the
OVP1
annunciator blinks.
– If the OVP trip occurs on Output 2, the display shows
triP
on line 2 and the
OVP2
annunciator blinks.
NOTE
To cancel this operation, allow the unit to idle for five seconds.