Operation and Features
2
Keysight U8030A Series User’s Guide
41
5 Adjust for the desired voltage limit.
– Press the
[Voltage/Current]
button if necessary until the
V
annunciator
blinks.
– While the
V
annunciator is blinking, turn the knob to adjust for the desired
output voltage value.
6 Adjust for the desired output current.
– Press the
[Voltage/Current]
button if necessary until the
A
annunciator
blinks.
– While the
A
annunciator is blinking, turn the knob to adjust for the desired
current limit value.
7 Return to the meter mode.
– Press the
[Display Limit]
button to return to the meter mode.
– The
LIMIT
annunciator turns off.
8 Enable the output.
– Press the
[Output 1 On/Off]
or
[Output 2 On/Off]
button to enable the
output.
– The
OFF
annunciator turns off and the
CC
annunciator turns on for the
corresponding output.
– The display is now in the meter mode.
NOTE
When you press the
[Display Limit]
button, the voltage and current limit values
will be shown on the display for about five seconds. If there is no activity
detected, the display will return to the meter mode.
NOTE
Verify that the power supply is in the constant current mode. Ensure that the
constant current (CC) annunciator is on. If the constant voltage (CV) annunciator
is on instead, choose a higher voltage limit.
Summary of Contents for U8030A Series
Page 2: ...Keysight U8030A Series Triple Output DC Power Supply User s Guide ...
Page 9: ...8 Keysight U8030A Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 13: ...12 Keysight U8030A Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 15: ...14 Keysight U8030A Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 17: ...16 Keysight U8030A Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...