Making Measurements
Making a Stimulus Response Transmission Measurement
55
Making a Stimulus Response Transmission
Measurement
The procedure below describes how to use a built-in
tracking generator to measure the rejection of a low
pass filter, a type of transmission measurement.
1 To measure the rejection of a low pass filter, connect
the equipment as shown below.
A 370 MHz low-pass filter is used as a DUT in this
example.
Figure 4-16 Transmission Measurement Test Setup
N9340A
HANDHELD SPECTRUM ANALYZER
100
kH z - 3.0
GHz
PRESET
ENTER
FREQ
SPAN
AMPTD
BW/
SWP
SYS
MODE
M EAS
TRACE
ESC/ CLR
2
D EF
3
GHI
1
ABC
5
M N O
4
JKL
6PQR
8
VWX
7
STU
9
YZ_
0
SAVE
LIM IT
M ARKER
DUT
2 Press [Preset] to perform a factory preset.
3 Set the start and stop frequencies and resolution
bandwidth:
•
Press [FREQ] > {Start Freq} > 100 > {MHz}
•
Press [FREQ] > {Stop Freq} > 1 > {GHz}
•
Press [BW/SWP] > {RBW} > 1 > {MHz}
4 Turn on the tracking generator and if necessary, set
the output power to –10 dBm:
Press [MODE] > {Track Generator} > {Amplitude (On)}
> –10 > {dBm}.
CAU-
CAUTION
Excessive signal input may damage the DUT. Do not exceed
the maximum power that the device under test can tolerate.
Summary of Contents for N9340B
Page 7: ...1 Overview 1 Overview ...
Page 42: ...System and File File 36 ...
Page 43: ...37 Making Measurements 4 Making Measurements ...
Page 150: ...Error Messages Error Message List 144 ...
Page 154: ...Troubleshooting Contact Keysight Technologies 148 Contact Keysight Technologies ...
Page 157: ...Menu Map AMPTD 151 ...