Error Messages
Error Message List
143
150
Mixer overload
Indicates the first mixer in danger. Either
increase input attenuation or decrease the
input signal level.
149
Mixer saturate
Indicates you need to either increase the
input attenuation or decrease the input
signal level.
147
Incorrect
alignment data in
EEPROM
Indicates invalid alignment data occurred.
143
Final IF overload
Indicates you need to either increase the
input attenuation or decrease the input
signal level.
138
USB device NOT
ready
Indicates the USB device is not detected.
136
RBW limit to
30 kHz when in
fast sweep
Indicates the analyzer automatically
couple the RBW to 30 kHz when in fast
sweep mode.
130
Meas uncal
Indicates the measurement is uncalibrated
due to fast sweeping through a narrow
RBW filter. Check the sweep time, span,
and bandwidth settings, or use auto
coupling.
119
RF Board Changed
Indicates the RF board was changed, the
analyzer needs re-load the alignment data.
116
Cannot communicate
with RF
Indicates the MCU cannot find the RF
board.
Error
Code
Error Message
Description