![Keysight Technologies N69100 Series Operating And Service Manual Download Page 202](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218202.webp)
TRIGger:ARB:SOURce <
source
>
TRIGger:ARB:SOURce?
TRIGger:TRANsient:SOURce <
source
>
TRIGger:TRANsient:SOURce?
TRIG:ARB:SOURce - Selects the trigger source for arbitrary waveforms:
TRIG:TRANsient:SOURce - Selects the trigger source for the transient system:
BUS
Selects a remote interface trigger command.
EXTernal
Selects ALL digital port pins that have been configured as trigger sources.
IMMediate
Triggers the transient as soon as it is INITiated.
PIN<1-7>
Selects a digital port pin configured as a trigger input.
Parameter
Typical Return
BUS | EXTernal | IMMediate | PIN<1-7> *RST BUS
BUS, EXT, IMM, PIN<n>
Select digital port pin 1 as the Arb trigger source: TRIG:ARB:SOUR PIN1
Select digital port pin 1 as the transient trigger source: TRIG:TRAN:SOUR PIN1
5 SCPI Programming Reference
202
Keysight N69100 Series Operating and Service Guide