MEASure[:SCALar]:CURRent:LOW?
MEASure[:SCALar]:VOLTage:LOW?
Initiates, triggers, and returns the Low level of a pulse waveform. Values returned are either in
amperes, or volts. See
.
Parameter
Typical Return
(none)
<LOW value>
Returns the measured low level voltage MEAS:VOLT:LOW?
MEASure[:SCALar]:CURRent:MAXimum?
MEASure[:SCALar]:CURRent:MINimum?
MEASure[:SCALar]:POWer:MAXimum?
MEASure[:SCALar]:POWer:MINimum?
MEASure[:SCALar]:VOLTage:MAXimum?
MEASure[:SCALar]:VOLTage:MINimum?
Initiates, triggers, and returns the maximum or minimum values of a measurement. Values returned
are either in amperes, volts, or watts.
Parameter
Typical Return
(none)
<MIN value>,
<MAX value>
Returns the measured maximum current MEAS:CURR:MAX?
Returns the measured minimum voltage MEAS:VOLT:MIN?
Returns the measured maximum power MEAS:POW:MAX?
Keysight N69100 Series Operating and Service Guide
183
5 SCPI Programming Reference