136 N5511A Phase Noise Test System User’s Guide
Absolute Measurement Examples
Dual Channel (DCFM)
Configuring Equipment
Configure the equipment to the settings for this lab:
1) Power
Power on all the equipment: Keysight N5511A PNTS, PSGs
2) Set up the DUT
Frequency,
1 GHz
Amplitude
,
14 dBm
RF On/Off
,
On
3) Set up REF 1
Frequency,
1 GHz
Amplitude
,
14 dBm
FM
,
FM Dev
,
1 kHz
More,
Ext Impedance
,
600 Ohm
RF On/Off
,
On
Mod
,
On
4) Set up REF 2
Frequency,
1 GHz
Amplitude
,
14 dBm
FM
,
FM Dev
,
1 kHz
More,
Ext Impedance
,
600 Ohm
RF On/Off
,
On
Mod
,
On