12.5 - Error code examples
Error
Description
E00
No communication between function selector and equipment. The incorrect or absence of connection of the function
selector causes the appearance of the error E 00 on the display of the PRO selector and non-operation of the
equipment display
E101
Obstacle detected with closing current. The equipment continues normal operation.
E201
Obstacle detected due to encoder stopped during closure. The equipment continues normal operation.
E102
Obstacle detected with opening current. The equipment continues normal operation.
E202
Obstacle detected with encoder stopped in opening. The equipment continues normal operation.
E03
Faulty encoder. The equipment stops and will only attempt to resume operation after being reset or turned off.
E04
Power supply absent. The equipment continues operation, as set with parameter F.
E05
Low battery. The equipment normally continues operation as long as the battery voltage permits it.
E06
Learned stroke greater than the maximum permitted. The equipment will only attempt to resume operation after
being reset or turned off.
E07
Flat battery. The equipment stops.
E08
Motor polarity reversed or encoder channels reversed. The equipment stops and will only attempt to resume
operation after being reset or turned off.
E09
Weight detected higher than the max. permissible. The equipment will only attempt to resume operation after being
reset or turned off.
E10
Motor current greater than the maximum permissible detected.
The equipment will attempt to resume operation after a new command.
E11
Overload protection of the power circuit has occurred. The equipment will attempt to resume operation after a new
command.
E12
EEPROM memory read or write error The equipment will attempt to resume operation only after being reset or
turned off.
E13
Monitored device test 1 failed PHOTO command
E14
Monitored device test 2 failed PHOTO command
E15
Monitored device test 1 failed PHOTO RALL command
E16
Monitored device test 2 failed PHOTO RALL command
E17
Monitored device test 1 failed STOP command
E18
Monitored device test 2 failed STOP command
E19
Excessive temperature of the power electronics. The equipment will only attempt to resume operation after being
reset or turned off.
E20
Power electronics failure, The equipment will only attempt to resume operation after being reset or turned off.
ESC
MENU
OK
PROGRAM MENÙ
P5
P4
P1
P2
AS
P1
ESC
OK
P2
Summary of Contents for TELESCOPIC LEVANTE
Page 39: ...39 IT NOTE ...
Page 77: ...77 EN NOTE ...
Page 115: ...115 ES NOTAS ...
Page 153: ...153 FR REMARQUES ...
Page 154: ...EN 154 NOTE ...