43
EN
2 - INTRODUCTION TO THE PRODUCT
2.1 - Product description
2.2 - Technical specifications
1- 24V transformer unit
2- Motor unit
3- Control unit
4- Guide pulley with tensioner unit
1- Thrustbearing column
2- “L” thrustbearing bracket
3- Runner
4- Round belt guide
5- Mechanical limit switch
6- Runner
7- Right side cap
8- Left side cap
5- Round belt guide with belt tensioner
6- Fixed belt lock
7- Connecting bracket between the panels with movable belt lock
8
Power supply
230 Vac (+/- 10%) 50/60 Hz
Rated power
130 W
Electric lock voltage
12 Vdc, 5 W
Battery charger
27.6 Vdc max, I max = 350 mA max during charging
Electric motor
24 Vdc max power 80 VA
Recommended max. weight for panel
1+1 leaf 100+100 Kg; 2+2 leaves 70+70 + 70+70Kg
Opening speed
Adjustable max 80 cm/s (for leaf in weight class “0”)
Closing speed
Adjustable max 50 cm/s (for leaf in weight class “0”)
Opening pause time
Adjustable from 0 to 60 seconds
Operating temperature
from -20°C to +55°C
Protection rating
IP 22
Crosspiece length
max 7 m
Fuse 1 power line
15A blade fuse type AL
Auxiliary battery power supply fuse
15A blade fuse type AL
Accessories power outlet
28V max, with 500mA max
Use in highly acid, saline or explosive atmosphere
NO
2.3 -
Wiring table
It is advisable to run the cables to the far right, looking at the automation box, with a cable excess of approximately 3 m.
Power supply 230V
Max length [m]
Cable type
3
H05VV-F 3G1 mm²
Control inputs
Inputs
Max length [m]
Cable type
OPEN CLOSE
30
PVC LiYY 5x0.34mm²
START STOP
5
4
6
3
2
1
2
4
6
3
5
7
7
1
The motorised front beam consists of the following sub-assemblies:
The rear telescopic beam consists of the following sub-assemblies:
Summary of Contents for TELESCOPIC LEVANTE
Page 39: ...39 IT NOTE ...
Page 77: ...77 EN NOTE ...
Page 115: ...115 ES NOTAS ...
Page 153: ...153 FR REMARQUES ...
Page 154: ...EN 154 NOTE ...