7.4 - Connection between fast panel (front) and slow panel (rear)
Connect the bracket of the mobile belt block coming from the
telescopic beam (rear) to the runner of the front panel facing the
OPENING
CLOSING
opening direction and in the position of the most rearward holes
(see chapter “Installation dimensions”).
8 - POSITIONING AND WIRING OF THE MODULES INSIDE THE BEAM
8.1 - Positioning of the modules inside the beam
Once the beam has been fixed and the panels are prepared, the
modules are positioned according to the previous diagrams, section
“Installation Dimensions - top and front views”. Follow the order
indicated:
1- Control unit
2- Transformer
3- Motor
4- Guide pulley.
When positioning the motor, pay attention to the transformer cables:
they must pass through the slot on the beam above the motor.
1
2
3
8.2 - Wiring of the modules inside the beam
The following figures show the motor wiring on the control unit.
Check the positions of each module in the chapter “Installation
dimensions”. The 24 V cable coming from the transformer
The motor power supply is connected to terminal CN3 in position:
23 (M2) black cable
22 (M1) red cable
.
It is important to respect the directions indicated. If the polarity is
reversed the door will work in reverse.
secondary is passed into the appropriate guide above the motor
and connects to the control unit in terminal CN1 pos. 24 (AC) and
pos. 25 (AC), as shown in the figure
TRANSFORMER
MOTOR
ESC
MENU
OK
PROGRAM MENÙ
CN6
1
2
3
4
5
6
7
10
11
12
13
14
15
25
24
23
22
21
20
N
M
L
I
16
17
A B C D E F G H
18
19
8
9
CN8
CN1
CN2
CN3
CN4
ENCODER
M2
- ENC
A ENC
B ENC
+ ENC
M1
ELB
ELB
AC
AC
CN7
CN5
CN11
CN9
CN10
CNP
P1
P5
P4
P1
P2
AS
START F.I.