BOP HIPWR 111315
3-27
5. Continue to modify parameters as described in step 4 above. When all parameters have
been modified, press
$
to save for power-up. Press
%
to exit without storing the
changes.
NOTE: If the message CHANGES NOT ALLOWED is displayed, the memory location has been
remotely locked (see PAR. A.12 for details).
6. After the changes have been saved, the unit returns to the Saved Settings screen, where
the saved settings can now be applied to the output by pressing
@
.
3.3.8.4
COPYING PREVIOUSLY SAVED SETTINGS TO A NEW LOCATION
1. Press
!
from the power-up screen to enter the Saved Setups screen (Figure 3-8).
2. Use the
U
and
Y
keys to highlight the location to be copied, then press
$
.
3. Highlight an
Empty
location and press
$
to save to the highlighted location, or press
%
to
abort the copy.
3.3.8.5
APPLYING SAVED SETTINGS TO THE OUTPUT (RECALL)
1. Press
!
from the power-up screen to enter the Save/Recall menu.
2. Use the
U
and
Y
keys to highlight the desired memory location. When the desired location
is highlighted, press
!
to view the detailed settings before execution, or press
@
to apply
the settings to the output. Refer to PAR. 3.3.8.3 to modify a setting before execution.
3.3.9
WAVEFORM GENERATION
3.3.9.1
PROTECTING THE LOAD WHEN ACCESSING WAVEFORMS
CAUTION: Before
Pressing
@
to enter the Saved Waveform Screen from the power-up
screen, perform the following steps to avoid unexpected voltages or currents
from previous settings being briefly applied to the load when the waveform
is first executed.
1. Use the MODE key to set the operating mode of the unit (voltage or current) to correspond
with the mode of the waveform.
2. Set the main channel to zero, and the protection channel to maximum. This ensures that the
waveform will start from zero. Otherwise, between pressing STANDBY to turn the output on,
and pressing
$
to execute the waveform, the previously programmed settings of the power
supply will be applied to the load until the waveform starts executing.
3.3.9.2
WAVEFORM OVERVIEW
After observing the precautions of PAR. 3.3.9.1, the Saved Waveforms screen (Figure 3-9) is
entered by pressing
@
from the power-up screen (Figure 3-3). Waveforms that have been pre-
viously saved will be displayed with the previously assigned names; waveforms that have been
erased will appear as Empty. Up to 16 separate local waveforms can be programmed and
stored from the front panel.
Summary of Contents for BOP-MG 1KW
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 40: ......
Page 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 68: ......