A-4
BIT 4886 111315
A.9
*OPT? — OPTIONS QUERY
*OPT?
Syntax
:
*OPT?
Returns string determined by power supply model.
Description:
Causes the power supply to return an ASCII string which defines the functionality of the power
supply.
The functionality is defined as follows:
A.10
*RCL — RECALL COMMAND
*RCL
Syntax
:
*RCL <integer> (1 to 99)
Description:
Restores power supply to previously defined levels of output voltage, output current and trig-
gers.
This command selects one of the 99 power supply memory locations, each of which stores val-
ues for output current and output voltage. Executing a *RCL recalls the stored settings (see *SAV,
PAR. A.12, for details) from the specified location (whether stored locally or using SCPI commands)
and applies them to the unit.
A.11
*RST — RESET COMMAND
*RST
Syntax
:
*RST
Description:
Resets power supply.
Executing *RST has the following effects:
•
Stops any LIST command that is running
•
CURR:MODE (PAR B.27) and VOLT:MODE (PAR B.95) are both set to FIXed (transient is inac-
tive)
•
VOLT:PROT (PAR B.97) and CURR:PROT (PAR B.29) are both set to box values.
•
VOLT (PAR B.87) and CURR (PAR B.19) settings are both set to 0.
•
VOLT:PROT:MODE (PAR B.99) and CURR:PROT:MODE (PAR B.31) are both set to FIXed
•
FUNC:MODE (PAR B.45) is set to VOLTage
•
TRIG:SOUR (PAR B.148) set to BUS
•
CURR:TRIG (PAR B.43) and VOLT:TRIG (PAR B.111) both set to 0
•
FUNC:MODE:TRIG (PAR B.47) set to VOLTage
•
INIT:CONT (PAR B.6) set to OFF (trigger system is not armed)
•
Output set to either on or off, as determined by setting of
*RST set Output
from Interface settings
menu (see Table 3-16 and PAR. 3.5.3.1.3).
STRING DATA
MEANING
CCAL
Support for limit calibrations is present.
RL1
Commands sent over GPIB cause unit to enter remote mode.
MEMM
Computer location commands are supported.
LSTAPL
LIST Apply command is supported.
Summary of Contents for BOP-MG 1KW
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 40: ......
Page 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 68: ......