3-34
BOP HIPWR 111315
FIGURE 3-11. SAMPLE WAVEFORM
2. The initial waveform settings are displayed (see Table 3-11 and Table 3-12 for parameter
details. Use
!
to modify the initial settings for the waveform. For each parameter, use
$
to save the setting.
Name
CAP CHARG
Mode
VOLTAGE
Protection
Positive
10
Negative
10
Count
0
Segment
Type
Neg Ramp
Frequency (Hz)
50
Amplitude (p-p)
4
Offset
8
When all settings are complete, press
$
to save for power-up. This step creates a repeat-
ing negative ramp starting at +10V decreasing to +6V since it is a 4V p-p signal riding on an
8V offset. The frequency of 50 Hz establishes the time duration of 20 ms for the segment.
3. From the Waveform Settings screen, highlight segment NEG RAMP 50.0HZ 4.00 R and
press
@
to insert a new segment. Use
!
to modify the following settings of the new seg-
ment. For each parameter, use
$
to save the setting.
Type
Level
Period (Sec)
0.002
Offset
0
Initial/Repeat
Initial
When complete, press
$
to save for power-up. This step changes the 2ms, 0V level to be
executed only once at the beginning of the waveform.
4. From the Waveform Settings screen, highlight segment LEVEL 0.002s 0.00 I and press
@
to insert a new segment. Use
!
to modify the following settings of the new segment. For
each parameter, use
$
to save the setting.
Type
Level
Summary of Contents for BOP-MG 1KW
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 40: ......
Page 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 68: ......