LIST OF
WARNINGS AND CAUTIONS
BOP 1KW OPR 11/13/15
G/(H Blank)
PAGE
WARNING/CAUTION
3-19
CAUTION:
When working with active loads, always adjust the BOP protection limits
to be above the maximum values of voltage or current expected from the
load. For example, when the BOP is operating in voltage mode sinking
energy from a constant current type load, set the current protection limits
of the BOP above the maximum current expected from the load.
3-21
CAUTION:
When working with battery mode, if the output is set to ON by *RST (see
PAR. 3.5.3.1.3) and the battery is charged above 0.01V, the unit will sink
105% of I
O
max.
3-27
CAUTION:
Before Pressing
@
to enter the Saved Waveform Screen from the power-
up screen, perform the following steps to avoid unexpected voltages or
currents from previous settings being briefly applied to the load when the
waveform is first executed.
3-36
CAUTION:
Pressing RESET will cause voltage transients to appear at the output
which may damage a connected load. Switch is recessed to prevent inad-
vertent activation.
3-45
CAUTION:
The commands listed above with (**) will generate a “-440, Missing Que-
ry” error if a query does not precede the command in the same command
string or
;*OPC?
does not follow the command. Although commands not
marked with (**) will not generate an error, all commands listed above re-
quire verification to insure absolute success. Failure to follow these
rules can result in the loss of all stored constants and render the unit in-
operative.
3-53
CAUTION:
When the serial port has received an XOFF, the error message “-400, Que-
ry Error” will be placed in the queue to indicate the loss of transmitted in-
formation due to a received XOFF character. When XON is received, the
unit will transmit all data in it's buffer followed by the exclamation char-
acter (!). This (!) character is not part of any message from the BOP and
indicates the transmission buffer has been cleared and the BOP is idle.
4-11
CAUTION:
If the CALIBRATE ZERO
!
function is available, perform this function
first, as it affects all other output calibrations.
Summary of Contents for BOP-MG 1KW
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 40: ......
Page 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 68: ......