3-36
BOP HIPWR 111315
3.3.10
RESET
CAUTION: Pressing RESET will cause voltage transients to appear at the output which
may damage a connected load. Switch is recessed to prevent inadvertent
activation.
Pressing
RESET
causes the power supply to execute a complete power on sequence to reset
the power supply to the power up settings (see PAR. 3.3.7).
3.3.11
OPERATOR TESTING
The Test System submenu is entered by pressing
%
from the power-up screen, then highlight
Revision/Test and press
!
. Upon power-up all tests are flagged as
Untested
. Table 3-13 lists
the tests that can be run. Highlight the choice and press
#
to run the selected test.
3.3.12
ERROR MESSAGE EXPLANATIONS
When a key press is not accepted, an error message is displayed at the bottom of the screen.
Although recovery from most operator errors is obvious and simple, Table 3-14 lists all the error
messages along with associated explanations as to why they occurred.
TABLE 3-13. REVISIONS/TEST MENU
SETTING
CHOICES
(
BOLD
= Factory Default)
FUNCTION
MAXIMUM OUTPUT
VOLTAGE XX
CURRENT YY
(Cannot be highlighted)
XX.0
YY.0
Displays rated output voltage and current of power supply. including all slaves
connected in parallel or series.
TEST
DISPLAY
Status (see NOTE below)
Automatic test, reports status messages (see NOTE below).
KEYPAD
Status (see NOTE below)
Requires depressing keys indicated on LCD.
This test requires pressing every key on the keypad, plus moving the
ADJUST control clockwise and counterclockwise, with the ADJUST control
depressed and released. As the keys and control function pass the tests, the
corresponding function on the LCD is highlighted. When the last test is suc-
cessful, the LCD displays “passed.” The test must be completed within two
minutes, otherwise a “Failed” indication is displayed.
INTER-
FACE
Status (see NOTE below)
Automatic test, reports status messages (see NOTE below).
SERIAL
Status (see NOTE below)
Automatic test of serial port - requires installation of loop back test connector.
(see PAR. 3.5.6.4). Reports status messages (see NOTE below).
ANALOG
Status (see NOTE below)
Automatic test which does not affect unit output. Reports status messages
(see NOTE below).
OUTPUT
Status (see NOTE below)
WARNING: DANGEROUS VOLTAGES ARE PRESENT AT THE OUTPUT
TERMINALS: DO NOT TOUCH! DISCONNECT LOAD BEFORE RUNNING
THIS TEST.
Output is automatically programmed to +
E
Onom
then –
E
Onom
,
then to 0V. Test duration is less than 2 Seconds. Reports status messages
(see NOTE below).
REVISIONS
DISPLAY
INTERFACE
ANALOG
(Cannot be highlighted)
x.xx
y.yy
z.zz
Displays current firmware revision for display, interface and analog proces-
sors.
NOTE: Test status is as follows:
UNTESTED
Initial status when first entering menu.
TESTING
Test is running.
PASSED
Test was successful.
FAILED
Test failed.
FAIL EXT
SERIAL test failed - verify loop back connector installed (see PAR. 3.5.6.4).
Summary of Contents for BOP-MG 1KW
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 40: ......
Page 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 68: ......