BOP HIPWR 111315
3-53
FIGURE 3-17. RS 232 IMPLEMENTATION
Only seven control characters (characters between 00
H
and 1F
H
) are acknowledged by the
power supply:
•
Carriage Return (CR, 0D
H
)
•
Line Feed (LF, 0A
H
)
•
Back Space (BS, 08
H
)
•
Escape (ESC, 01B
H
)
•
XON (011
H
)
•
XOFF (013
H
)
•
CAN (018
H
)
BS deletes the last character entered, with the exception of CR or LF characters. Either the CR
or LF character acts as the line terminator, initiating parsing of the ASCII data sent to the BOP
by the command originator. When the line is parsed and the commands are sent to the analog
processor, the BOP sends the line terminator sequence CR LF to the command originator.
The ESC character is used for synchronization, causing the BOP to reset its input buffer and
return a CR LF sequence.
The XON character enables the transmitter if XON/XOFF flow control is enabled (see PAR.
3.5.3.2.2 and Table 3-16).
The XOFF character stops data transmission if XON/XOFF flow control is enabled (see PAR.
3.5.3.2.2 and Table 3-16).
The CAN character resets the receive and transmit pointers and queues.
CAUTION: When the serial port has received an XOFF, the error message “-400, Query
Error” will be placed in the queue to indicate the loss of transmitted informa-
tion due to a received XOFF character. When XON is received, the unit will
transmit all data in it's buffer followed by the exclamation character (!). This
(!) character is not part of any message from the BOP and indicates the
transmission buffer has been cleared and the BOP is idle.
Summary of Contents for BOP-MG 1KW
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 40: ......
Page 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 68: ......