BOP 5-20DL 081915
The logic status signals shown in Figure 3-28 are valid for the BOP operating in voltage mode
(E
O
MODE) and local mode (not driven by the GPlB interface). The BOP 5-20DL uses the front
panel REMOTE ON-OFF indicator shows the output on-off status as determined by signals
applied to the OUTPUT ON-OFF Port.
3.8
DIGITAL CONTROL OF BOP POWER SUPPLIES.
The BOP 5-20DL is configured with a remote output ON-OFF PORT which interfaces electrically
and mechanically with the digital control assembly used by a BIT Interface card which must be
installed for digital control. If digital control is required, contact Kepco to disable the output ON-
OFF PORT and allow installation of the optional BIT interface card. Digital control options avail-
able are via either GPIB and RS 232 using a BIT 4886 Interface Card, or ethernet/LAN using a
BIT 802E Interface card. Both cards are compliant with IEEE 488 and SCPI commands and
queries. For more details, see www.kepcopower.com/bit.htm.