NX-200
98
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
10. Single
Tone
Deviation
adjust
*4
[Narrow]
1) Adj item: [An TONE]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Analog Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[ ],[ ]
Write the value as
followings.
513 (Reference
value)
1.50kHz±0.05kHz
[Wide]
1) Adj item: [Aw TONE]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Analog Wide)]
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
3.00kHz±0.05kHz
11. MSK
Deviation
adjust
*4
[Narrow]
1) Adj item: [An MSK]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Write the value as
followings.
513 (Reference
value)
1.50kHz±0.05kHz
[Wide]
1) Adj item: [Aw MSK]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Analog
Wide)]
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
3.00kHz±0.05kHz
12. CWID
Deviation
adjust
*4
[Very
Narrow]
1) Adj item: [Nv CWID]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [CW ID
Deviation (NXDN
Very Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Write the value as
followings.
376 (Reference
value)
1.10kHz±0.10kHz
*4: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 102.