NX-200
100
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
13. VOX1
adjust
1) Adj item: [VOX1]
Adjust:
[
✳✳✳
]
AG: 1kHz/45mV at
MIC terminal
1) Adj item: [VOX1]
AG: 1kHz/45mV at
MIC terminal
AG
Panel
Universal
connector
[Panel tuning mode]
After apply signal
from AG, press [ ]
key to store the
adjustment value.
[PC test mode]
After apply signal
from AG, press
[Apply] button to
store the adjust-
ment value.
14. VOX10
adjust
1) Adj item: [VOX10]
Adjust:
[
✳✳✳
]
AG: 1kHz/3mV at
MIC terminal
1) Adj item: [VOX10]
AG: 1kHz/3mV at
MIC terminal
15. BATT
detection
writing
1) Adj item: [BATT]
Adjust:
[
✳✳✳
]
PTT:
ON
1) Adj item:[Battery
Warning Level]
PTT:
Press
[Transmit] button.
Power
meter
DVM
Panel
ANT
BATT
terminal
Press the PTT
switch or [Transmit]
button on the PC
window.
Apply 6.20V to bat-
tery terminal.
Confi rm that one
pre-determined nu-
meric in the range 1
to 256 appears.
[Panel tuning mode]
Press [ ] key to
store the adjust-
ment value.
[PC test mode]
Press [Apply] but-
ton to store the
adjustment value.
16. BATT
detection
check
[Panel test mode]
1) CH-Sig: 1-1
BATT
terminal
voltage: 6.0V while
transmitting
1) Test Channel
Channel: 1
Test
Signaling
Mode: Analog
Signaling: 1
BATT
terminal
voltage: 6.0V while
transmitting
Check
The transceiver
can transmit with
causing the LED to
blink.