NX-200
110
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. Low RSSI
at –118dBm
adjust
*7
[Analog
Narrow]
1) Adj item: [An
LRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[AnL
LRSSI]
→
[AnL’
LRSSI]
→
[AnC
LRSSI]
→
[AnH’
LRSSI]
→
[AnH
LRSSI]
Adjust:
[
✳✳✳
]
SSG
output:
–118dBm
(0.28µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [Low RSSI
(Analog Narrow)]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
SSG
output:
–118dBm
(0.28µV)
(MOD: 1kHz/±1.5kHz)
SSG
Panel
ANT
Universal
connector
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
[Analog
Wide]
1) Adj item: [Aw
LRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[AwL
LRSSI]
→
[AwL’
LRSSI]
→
[AwC
LRSSI]
→
[AwH’
LRSSI]
→
[AwH
LRSSI]
Adjust:
[
✳✳✳
]
SSG
output:
–118dBm
(0.28µV)
(MOD: 1kHz/±3kHz)
1) Adj item: [Low RSSI
(Analog Wide)]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
SSG
output:
–118dBm
(0.28µV)
(MOD: 1kHz/±3kHz)
[NXDN
Very
Narrow]
1) Adj item: [Nv
LRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[NvL
LRSSI]
→
[NvL’
LRSSI]
→
[NvC
LRSSI]
→
[NvH’
LRSSI]
→
[NvH
LRSSI]
Adjust:
[
✳✳✳
]
SSG
output:
–118dBm
(0.28µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [Low
RSSI (NXDN Very
Narrow)]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
SSG
output:
–118dBm
(0.28µV)
(MOD: 1kHz/±1.5kHz)
Adjust with the ana-
log signal.
*7: Because Low RSSI at –118dBm (NXDN Narrow) is adjusted by adjusting Low RSSI at –118dBm (Analog Narrow), it is not necessary to adjust
Low RSSI at –118dBm (NXDN Narrow).