ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
7. DQT
Deviation
adjust
*4
[Narrow]
1) Adj item: [An DQT]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [DQT
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[ ],[ ]
Write the value as
followings.
415 (Reference
value)
0.35kHz±0.05kHz
[Wide]
1) Adj item: [Aw DQT]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [DQT
Deviation (Analog
Wide)]
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
0.75kHz±0.05kHz
8. LTR
Deviation
adjust
*4
[Narrow]
1) Adj item: [An LTR]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [LTR
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Write the value as
followings.
465 (Reference
value)
0.75kHz±0.05kHz
[Wide]
1) Adj item: [Aw LTR]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [LTR
Deviation (Analog
Wide)]
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
1.00kHz±0.05kHz
9. DTMF
Deviation
adjust
*4
[Narrow]
1) Adj item: [An DTMF]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Write the value as
followings.
540 (Reference
value)
1.25kHz±0.05kHz
[Wide]
1) Adj item: [Aw DTMF]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Wide)]
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
2.50kHz±0.05kHz