ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
7. Frequency
adjust
* The Frequency
adjustment can be
performed only in
PC test mode.
1) Adj item:
[Frequency]
SSG output :
–20dBm (22.4mV)
(CW (without
modulation))
Caution:
Perform the frequency
adjustment under the
following conditions.
• Temperature range
of +23˚C to +27˚C
(+73.4˚F to +80.6˚F).
(The temperature
is displayed on the
Frequency adjust-
ment screen of
the KPG-111D(C)
and the LCD of the
transceiver.)
• Use an accuracy of
0.003ppm for the
SSG. (Use a stan-
dard oscillator if
necessary.)
SSG
Panel
ANT
Panel
[Side1]
[PC test mode]
Press [Start] button
of “Auto Tuning”.
Press [Apply] but-
ton to store the
adjustment value
after the automatic
adjustment was
fi nished.
[PC test mode]
The value of “IF20”
will become around
“0” after the adjust-
ment was fi nished.
Remark:
“Frequency” is
adjusted under
receiving condition
with SSG.
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. High
Transmit
Power
adjust
(Battery
voltage:
7.5V)
1) Adj item: [HIPWR]
Adjust:
[
✳✳✳✳
]
2) Adj item:
[L
HIPWR]
→
[L’
HIPWR]
→
[C
HIPWR]
→
[H’
HIPWR]
→
[H
HIPWR]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [High
Transmit Power]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
PTT:
Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Power
meter
Ammeter
Panel
ANT
Panel
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[ ],[ ]
5.0W
±0.2W
2.0A or less
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
point was adjusted.
2. Low
Transmit
Power
adjust
(Battery
voltage:
7.5V)
1) Adj item: [LOPWR]
Adjust:
[
✳✳✳✳
]
2) Adj item:
[L
LOPWR]
→
[L’
LOPWR]
→
[C
LOPWR]
→
[H’
LOPWR]
→
[H
LOPWR]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press
[ ] key to
store the adjust-
ment value.
1) Adj item: [Low
Transmit Power]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
PTT:
Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
0.8W
±0.1W
1.0A or less
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment